Crew 182 Operations Report 10Nov2017
SOL: 7
Name of person filing report: Carmen Atauconcha
Non-nominal systems:
WATER HEATER: It is not working. Today we wanted to take a shower and the water was cold. The heater is not heating the water. We opened the entire water pipe, but it still did not heat.
COMMUNICATION RADIOS: One of the radios is making a special noise constantly. Like every 3-5minutes it sounds, even if we leave it charging.
SECONDARY AIRLOCK: The door of the secondary airlock is gotten out-off-square.
ATV’s: The blue ATV is not working. When we try to turn it on, it does not answer.
Generator— Operating from 09 November, 2017 at 5pm and currently working. 26 hours.
Solar—
READING FROM 10 NOV 2017
TIME | SOC READING |
8:00 AM – 17:00 PM | 100% |
READING FROM 09 NOV 2017.
TIME | SOC READINGS |
8.43 am | 98% |
9.13 am | 98% |
9.43 am | 98% |
10.09 am | 100% |
10.39 am | 100% |
12.20 pm | 100% |
13.01 pm | 98% |
13.38 pm | 96% |
13.46 pm | 95% |
13.56 pm | 94% |
14.11 pm | 93% |
14.34 pm | 100% |
15.19 pm | 100% |
16.28 pm | 98% |
17.31 pm | 93% |
Diesel – 59 %
Propane – 51 psi
Gasoline (5 Gallon containers for ATV) – 1/4 gallons
Water (trailer) – 0 gallons
Water (static) – 275 gallons
Trailer to Static Pump used – no
Water (loft) – Static to Loft Pump used – yes
Water Meter: 66.8 gallons
Toilet tank emptied: yes
ATV’s Used: RED ATV
Oil Checked: yes
Atv # Fuel Used Gals: 1 gal
Tires Status: Perfect
# Hours the ATVs were Used today: 1 and ½ hours
Deimos used: Yes
Hours: 1 and a ½ hours
Beginning charge: 12:30 pm
Ending charge:
Currently charging: Yes
HabCar used? No
Notes and Comments:
Today we had an advance in the topic about recycling water. The number of gallons of water that we used today is less than the gallons of water used yesterday. And, I know that tomorrow is going to be better.
Summary of Hab operations:
We put the jumper cables delivered on the lower shelf in the EVA room. Also, we fixed the radios because some of them did not have a good sound. In addition, tomorrow we are going to receive new communication radios.
Summary of GreenHab operations:
We are going to heat the greenhouse tomorrow
Summary of ScienceDome operations:
We installed the autoclave perfectly. Even, it has already been used once without any difficulty. At the same time, tomorrow we are going to receive a new shop vac.
Summary of health and safety issues:
The HOS officer needs two fire alarms for the science dome and for the greenhouse.
Questions, concerns and requests to Mission Support:
We need you to repair the heater water, since it still does not work.
For the next week at the most on Monday, we are going to need water.
I have a doubt, which is the minimum limit for the propane tank and the diesel tank?
Where does the used water go?