Operations Report
Crew 219 Operations Report 12-JAN-2020
Sol: 7
Name of person filing report: Alejandro Perez
Non-nominal systems: N/A
Generator: Run
Hours run: 17
From what time last night: 15:00
To what time this morning: 08:00
List of any additional daytime hours when the generator was run: N/A
Solar- SOC% (Before the generator is run at night): 82%
09:40 = 94%; 11:00 = 90%; 11:50 = 88%; 12:55 = 100%; 14:10 = 99%;
15:10 = 97%; 16:15 = 94%; 17:05 = 90%; 18:15 = 82%
Diesel Reading – 60%
Station Propane Reading- 40%
Ethanol Free Gasoline- N/A
Water (loft tank) (gal) – 50
Water Meter (units)- 0147603,1
Water (static tank) (gal) – 411
Static to loft Pump used –Yes
Water in Green Hab (gal): 174.86
Water in Science Dome (gal): 0
Toilet Tank Emptied –No
Diemos rover used: Still in the Work shop
Hours:
Beginning Charge:
End Charge:
Currently Charging:
Sojourner rover used: Yes, by Outpost
Hours:
Beginning Charge:100 %
End Charge: 21%
Currently Charging: Yes
Spirit Rover used- No
Starting Hours:
Beginning Charge:
Ending Hours:
Ending Charge:
Opportunity Rover used: Still in workshop
Hours:
Beginning Charge:
Ending Charge:
Currently Charging:
Curiosity Rover used: Yes, by Outpost
Starting Hours:
Beginning Charge: 100%
Ending Hours: 31%
Ending Charge: Yes
Notes on Rovers: Opportunity and Deimos off-site for maintenance.
ATV’s Used: (Honda, 300, 350.1, 350.2, 350.3): No
Reason for use:
Oil Added? No
# hours the ATV’s were used today:
Notes on ATVs:
Habcar used and why, where?
CrewCar used and why, where?
General Notes and Comments:
Summary of the internet: Nominal
Summary of Suit and Radios: Nominal
Summary of Hab: SOS’s were delivered. Repair to loft tank feedline is
working properly, however, the joint connecting the pipe going into
the loft tank is still leaking even with the new Teflon tape added.
Summary of Science Dome operations: Temperatures are hovering around 7
°C during the day.
Summary of Ram operations: Nominal
Summary of any observatory issues: Nominal
Summary of Health and safety issues: Nominal
Questions, concerns, and requests to Mission Support: ¾ in. M-M metal
threaded coupling for feedline pipe.