Supplemental Operations Report – February 18th

Date: 2/18/2024
Name of person filing report: Ben Stanley
Reason for Report: Routine
Non-Nominal Systems: Hab wall heater, solar observatory, perseverance parking brake

Power system:
Solar: Nominal.
SOC Last 24 hours: Max 98%; Min 39%; Avg 69.1%.
VDC Last 24 hours: Max 59.52V; Min 38.52; Avg 49.53V.
Generator run time: 5134.2 hours. Serviced on 02/18/2024, oil changed

Propane Readings:
Station Tank: 79%
Director Tank: 81%
Intern Tank: 83%
Generator Tank: 76%

Water:
Hab Static Tank – 550 gallons
GreenHab – 200 gallons
Outpost tank – 480 gallons
Science Dome – 0 gallons
Septic Tanks emptied: No

Rovers:
Sojourner rover used: No
Hours: 196.6
Beginning Charge: 100 %
Ending Charge: 100 %
Currently Charging: Yes
Notes on Rovers: Perseverance is back to normal.

ATV:
ATV’s Used: None. Nothing to report.

Cars:
Hab Car used and why, where: To Hanksville for supplies. Serviced on 2/12/24 – oil, oil filter, air filter, tires rotated, tire leak repaired, Mechanic note: looks like P/S cooler lines starting to leak
Crew Car used and why, where: In GJ with incoming crew
General notes and comments: N/A

Summary of Internet: All nominal.

EVA suits and radios:
Suits: All nominal
Comms: All nominal

Campus wide inspection, if action taken, what and why:
Sergii’s notes: remaining three fire extinguishers were serviced on 02/13/2024

Summary of Hab Operations: Wall heater is not functioning. Diagnostic is pending.
Summary of GreenHab Operations: All nominal
Summary of SciDome Operations: All nominal

Summary of Observatories Operations: Solar observatory telescope diagonal has two snapped screws. Repairs pending.

Summary of RAM Operations: All nominal
Summary of Outpost Operations: All nominal.
Summary of Health and Safety Issues: All nominal.

Copyright © The Mars Society. All rights reserved. | Main Site