Operations Report – November 6th

Crew 285 Operations Report 06-11-2023
SOL: 8
Name of person filing report: Tomás Ignacio Burroni
Non-nominal systems: None
Notes on non-nominal systems: N/A
ROVERS
Spirit rover used: No
Currently charging: Yes
Opportunity rover used: No
Currently charging: Yes
Curiosity rover used: No
Currently charging: Yes
Perseverance rover used: No
Currently charging: Yes
General notes on rovers: N/A
Summary of Hab operations: The higher water consumption today is due to the entire crew taking a shower. Everyone was limited to 1 min of water use, this resulted in around 10 to 12 gallons in total for the 6 members.
WATER USE: 35 gallons
Water (static tank): 289 gallons
Static tank pipe heater (on or off): on
Static tank heater (On or off): on
Toilet tank emptied: no
Summary of internet: No comments
Summary of suits and radios: After leaving the battery of suit N 10 to charge all night the voltage measured 12.6 V with the fan off and again dropped to 8.6 V with the fan on. The battery was changed for a new one as discussed yesterday. The new battery was measured before the first charge at 12.7 V with only a 0.2 V drop with the fan on. After 30 min charging it got to 13.5 V, measuring it after 1 h resulted in the same value, so the suit was disconnected and turned on. As soon as it was turned on, the voltage went down from 13.2 V to 12.6 V over the course of 1 min. 4 measurements were taken at 15 min intervals; it remained at 12.3 V. The last measurement was taken 2 hs after turn on, reading 12.2 V. We conclude from this test that the new battery works as expected. The suit is now off and charging along with the others.
Summary of GreenHab operations: sowed, watered, and harvested radish
WATER USE: 2.5 gallons
Heater: On
Supplemental light: Off
Harvest: Radish (75 grams)
Summary of ScienceDome operations: Not used today
Dual split: Off
Summary of RAM operations: Not used today
Summary of any observatory issues: None
Summary of health and safety issues: None
Questions, concerns and requests to Mission Support: I have marked the removed battery with tape as indicated by mission support yesterday, where should I leave it?

Operations Report – November 4th

SOL: 6
Name of person filing report: Tomás Ignacio Burroni
Non-nominal systems: None
Notes on non-nominal systems: N/A
ROVERS
Spirit rover used: No
Currently charging: Yes
Opportunity rover used: No
Currently charging: Yes
Curiosity rover used: No
Currently charging: Yes
Perseverance rover used: No
Currently charging: Yes
General notes on rovers: N/A
Summary of Hab operations:
WATER USE: 20 gallons
Water (static tank): 347 gallons
Static tank pipe heater (on or off): on
Static tank heater (On or off): on
Toilet tank emptied: yes
Summary of internet: No comments
Summary of suits and radios: None
Summary of GreenHab operations: separated the soil into different areas and watering
WATER USE: 2.5 gallons
Heater: On
Supplemental light: Off
Harvest: None
Summary of ScienceDome operations: Not used today
Dual split: Off
Summary of RAM operations: Not used today
Summary of any observatory issues:
Summary of health and safety issues: None
Questions, concerns and requests to Mission Support: The issue with the toilet sensor appeared again. This time the toilet tank indicator only went down to the ⅔ marking after emptying.

Operations Report – November 2nd

SOL: 4
Name of person filing report: Tomás Ignacio Burroni
Non-nominal systems: None
Notes on non-nominal systems: N/A
ROVERS
Spirit rover used: No
Currently charging: Yes
Opportunity rover used: Yes
Hours: 143.0
Beginning charge: 100%
Ending charge: 90%
Currently charging: Yes
Curiosity rover used: Yes
Hours: 256.3
Beginning charge: 100%
Ending charge: 69%
Currently charging: Yes
Perseverance rover used: No
Currently charging: Yes
General notes on rovers: N/A
Summary of Hab operations:
WATER USE: 19 gallons
Water (static tank): 387 gallons
Static tank pipe heater (on or off): on
Static tank heater (On or off): off
Toilet tank emptied: no
Summary of internet: An extra window was requested for today as we had an interview on live TV, both audio and video worked smoothly without any issues.
Summary of suits and radios: A single one-piece suit was lent to the filming crew. It was later cleaned and disinfected. No radio was given to them. We wish to note that the actor wearing it bumped it a couple of times while trying to enter the rover for the video. We will inspect it tomorrow in search of any new marks on the acrylic.
Summary of GreenHab operations: measurements and watering
WATER USE: 15 gallons
Heater: On
Supplemental light: Off
Harvest: None
Summary of ScienceDome operations: same as yesterday: used the blender, 3 large and 1 small paper filters, the microwave, the oven, 2 large erlenmeyer flasks, 1 large and 4 small beaker glasses, the scale, and the mortar and pestle. All this was used to recover starch from rice and potatoes and then mix it with a soil sample to create a concrete-like material. It was also used by the filming crew in the morning.
Dual split: Off
Summary of RAM operations: Used only by the filming crew
Summary of any observatory issues: None
Summary of health and safety issues: None
Questions, concerns and requests to Mission Support: As reported by the commander over the radio, today after the filming crew left we found toilet paper inside the toilet bowl and wet wipes in the burnable trash bin.

Operations Report – November 3rd

Crew 285 Operations Report 03-11-2023
SOL: 5
Name of person filing report: Tomás Ignacio Burroni
Non-nominal systems: None
Notes on non-nominal systems: N/A
ROVERS
Spirit rover used: Yes
Hours: 233.4
Beginning charge: 100%
Ending charge: 47%
Currently charging: Yes
Opportunity rover used: Yes
Hours: 143.1
Beginning charge: 100%
Ending charge: 57%
Currently charging: Yes
Curiosity rover used: Yes
Hours: 256.4
Beginning charge: 100%
Ending charge: 48%
Currently charging: Yes
Perseverance rover used: Yes
Hours: 275.3
Beginning charge: 99%
Ending charge: 46%
Currently charging: Yes
General notes on rovers: N/A
Summary of Hab operations:
WATER USE: 20 gallons
Water (static tank): 367 gallons
Static tank pipe heater (on or off): on
Static tank heater (On or off): off
Toilet tank emptied: no
Summary of internet: No comments
Summary of suits and radios: Attached is a picture of the marks found on the suit used by the actor yesterday. We are not sure which of these were already present as we had not used the one-piece suits previously.
Summary of GreenHab operations: sowing several plants and watering
WATER USE: 6.0 gallons
Heater: On
Supplemental light: Off
Harvest: None
Summary of ScienceDome operations: Not used today
Dual split: Off
Summary of RAM operations: Not used today
Summary of any observatory issues: None
Summary of health and safety issues: None
Questions, concerns and requests to Mission Support: None

Supplemental Operations Report – November 5th

Name of person filing report: Sergii Iakymov
Reason for Report: Routine
Non-Nominal Systems: Rovers: Perseverance, Curiosity, Spirit, Sojourner. A tunnel stick on the right from the rear airlock.

Power system:
Solar: Nominal.
SOC Last 24 hours: Max 100%; Min 19 %; Avg 54.4%.
VDC Last 24 hours: Max 58.58V; Min 43.59V; Avg 50.65V.
Generator run time: 3928.8 hours. Oil changed on 11/05/2023

Propane Readings:
Station Tank: 79%
Director Tank: 82%
Intern Tank: 85%
Generator Tank: 80%"

Water:
Hab Static Tank – 347 gallons
GreenHab – 168 gallons
Outpost tank – 350 gallons
Science Dome – 0 gallons
Hab Toilet Tank emptied: Yes

Rovers:
Sojourner rover used: No.
Hours: 195.4
Beginning Charge: 100 %
Ending Charge: 100 %
Currently Charging: Yes
Notes on Rovers: All rovers still waiting for all parts to arrive.

ATV: ATV’s Used: None. Nothing to report.

Cars:
Hab Car used and why, where: To Hanksville for supplies. Need to be serviced.
Crew Car used and why, where: To Hanksville for supplies.
General notes and comments: All cars awaiting renewed insurance ID.

Summary of Internet: All nominal.
EVA suits and radios:
Suits: All nominal
Comms: All nominal

Campus wide inspection, if action taken, what and why: One tunnel stick on the right from the rear airlock is corroded out at the ground level and needs to be replaced.
Summary of Hab Operations: Toilet tank level sensors need to be cleaned from toilet paper.
Summary of GreenHab Operations: All nominal
Summary of SciDome Operations: All nominal
Summary of Observatories Operations: Robotic observatory had a mount error but currently is operational. Solar observatory but nominal.
Summary of RAM Operations: Remote temperature sensor for smart home systems is offline. Most likely due to the battery being dead and it needs to be relocated to avoid touching metal walls.
Summary of Outpost Operations: Directors trailer thermostat was randomly offline three times. A new one is ordered to diagnose this issue.
Summary of Health and Safety Issues: All nominal.

Operations Report – November 1st

SOL: 3
Name of person filing report: Tomás Ignacio Burroni
Non-nominal systems: None
Notes on non-nominal systems: N/A
ROVERS
Spirit rover used: No
Currently charging: Yes
Opportunity rover used: No
Currently charging: Yes
Curiosity rover used: No
Currently charging: Yes
Perseverance rover used: No
Currently charging: Yes
General notes on rovers: N/A
Summary of Hab operations:
WATER USE: 23 gallons
Water (static tank): 406 gallons
Static tank pipe heater (on or off): on
Static tank heater (On or off): off
Toilet tank emptied: yes, the indicator only got to “⅓” instead of “empty”
Summary of internet: No comments
Summary of suits and radios: No comments
Summary of GreenHab operations: fertilization, thermostat adjusted to 65 F
WATER USE: 3.6 gallons
Heater: On
Supplemental light: Off
Harvest: None
Summary of ScienceDome operations: used the blender, 3 large and 1 small paper filters, the microwave, the oven, 2 large erlenmeyer flasks, 1 large and 4 small beaker glasses, the scale, and the mortar and pestle. All this was used to recover starch from rice and potatoes and then mix it with a soil sample to create a concrete-like material.
Dual split: Off
Summary of RAM operations: Not used today
Summary of any observatory issues: “Mount error” was fixed by the observatory director, however 2 hs later the “Camera error” showed up again, which stopped the image acquisition.
Summary of health and safety issues: None
Questions, concerns and requests to Mission Support: None

Operations Report – October 31st

SOL: 2
Name of person filing report: Tomás Ignacio Burroni
Non-nominal systems: None
Notes on non-nominal systems: N/A
ROVERS
Spirit rover used: Yes
Hours: 232.2
Beginning charge: 100%
Ending charge: 63%
Currently charging: Yes
Opportunity rover used: Yes
Hours: 142.9
Beginning charge: 100%
Ending charge: 85%
Currently charging: Yes
Curiosity rover used: Yes
Hours: 256.1
Beginning charge: 100%
Ending charge: 66%
Currently charging: Yes
Perseverance rover used: Yes
Hours: 275.2
Beginning charge: 100%
Ending charge: 74%
Currently charging: Yes
General notes on rovers: None
Summary of Hab operations:
WATER USE: 26 gallons
Water (static tank): 429 gallons
Static tank pipe heater (on or off): on
Static tank heater (On or off): on
Toilet tank emptied: no
Summary of internet: None
Summary of suits and radios: Radio number 4 at two points during the EVA started sending white noise to the user unless the user was pressing PTT. The solution was to turn it off and on again. We are unsure of the origin of the issue.
Summary of GreenHab operations: Inventory of growing plants, sowed new plants, measured ambient variables
WATER USE: 1.8 gallons
Heater: On
Supplemental light: Off
Harvest: None
Summary of ScienceDome operations: Not used today
Dual split: Off
Summary of RAM operations: Developed the mounting for the vibration sensor kit and took some tools for the EVA to place the sensors in the generator. Used: Safety glasses, clamps, pliers, dremel stand, power drill, bolts, nuts, and washers.
Summary of any observatory issues: The astronomy pictures of different targets show a circular stain; this could require cleaning the lens of the robotic observatory.
Summary of health and safety issues: None
Questions, concerns and requests to Mission Support: Non

Operations Report – October 30th

SOL: 1
Name of person filing report: Tomás Ignacio Burroni
Non-nominal systems: None
Notes on non-nominal systems: N/A
ROVERS
Spirit rover used: No
Currently charging: Yes
Opportunity rover used: No
Currently charging: Yes
Curiosity rover used: No
Currently charging: Yes
Perseverance rover used: No
Currently charging: Yes
General notes on rovers: N/A
Summary of Hab operations:
WATER USE: 30 gallons
Water (static tank): 455 gallons
Static tank pipe heater (on or off): on
Static tank heater (On or off): off
Toilet tank emptied: no
Summary of internet: Briefly stopped working shortly after being activated, at 1810. Started working again after ~2 min without intervention.
Summary of suits and radios: No comments
Summary of GreenHab operations: Inventory of growing plants, sowed new plants, measured ambient variables
WATER USE: 1.5 gallons
Heater: On
Supplemental light: Off
Harvest: None
Summary of ScienceDome operations: Not used today
Dual split: Off
Summary of RAM operations: Replicated a metal tab from the generator in cardboard with a cutter to test different mounting options for the sensor kit to correctly plan the EVA.
Summary of any observatory issues: Summary of any observatory issues: During captures with the deep space telescope one of two errors show up at some point during the night "Mount error” or “Camera error”. Hypothesis: the error is caused by the power switch between the battery and the generator. Questions to evaluate the hypothesis: Does the observatory have an active UPS? Could we do a controlled experiment with a very short capture and switch the power supply at a known time to see if the error shows up?
Summary of health and safety issues: None
Questions, concerns and requests to Mission Support: None

HSO Beginning Of Mission Checklist – October 29th

HSO BEGINNING OF MISSION CHECKLIST 2022-2023
Submitted by: Andrea de la Torre Aceves
Crew: 285
Date: October 29th, 2023
Part 1: Using the attached Safety Equipment Inventory, locate, test and confirm operation of all safety equipment. List any equipment not found and/or missing:
Intercom is missing in HAB Lower deck.
Eyewash is missing in ScienceDome.
Small fire extinguisher is missing in the HAB Upper deck.
Fire extinguisher in HAB Upper deck needs to be filled (last checked May 2023)
Locate, test and confirm operation of the following:
Smoke alarms
Upper deck: operational
Lower deck: operational
RAM: operational
GreenHab: operational
ScienceDome: operational
CO alarms
Upper deck: operational
Lower deck: operational
GreenHab: operational
RAM: operational, but it is not in the inventory
ScienceDome: operational, but it is not in the inventory.
Propane alarm
Lower Deck: operational
Upper deck: operational
Fire extinguishers
Upper deck: needs to be filled (last checked May 2023)
Lower deck: functional (last checked July 2023)
GreenHab: functional (last checked June 2023)
ScienceDome: functional (last checked June 2023)
RAM: functional (last checked June, 2023)
Fire blankets
Upper deck: on site
RAM: on site
ScienceDome: on site
Intercom
Upper deck: on site and functional.
HAB Lower deck: is missing.
RAM: on site and functional.
GreenHab: on site and functional.
ScienceDome: on-site and functional.
Escape ladder
Upper deck: on site and functional.
Nightlight
HAB Lower deck: functional
RAM: functional.
Radios (Channels 10 and 22)
Upper deck: on site and functional.
HAB Lower deck: on site and functional.
RAM: on site and functional.
GreenHab: on site and functional.
ScienceDome: on site and functional.
Tow rope: Found in spirit and functional.

Supplemental Operations Report – October 29th

Name of person filing report: Sergii Iakymov
Reason for Report: Routine
Non-Nominal Systems: Rovers: Perseverance, Curiosity, Spirit, Sojourner. A tunnel stick on the right from the rear airlock. GreenHab moisture meter. See below for details.

Power system:
Solar: Nominal.
SOC Last 24 hours: Max 100%; Min 76 %; Avg 89.9%.
VDC Last 24 hours: Max 58.69V; Min 46.15V; Avg 50.52V.
Generator run time: 3876.5 hours.

Propane Readings:
Station Tank: 71%
Director Tank: 46%
Intern Tank: 65%
Generator Tank: 66%

Water:
Hab Static Tank – 530 gallons
GreenHab – 200 gallons
Outpost tank – 450 gallons
Science Dome – 0 gallons
Hab Toilet Tank emptied: Yes

Rovers:
Sojourner rover used: No.
Hours: 195.4
Beginning Charge: 100 %
Ending Charge: 100 %
Currently Charging: Yes
Notes on Rovers: Perseverance – passenger and driver side battery sensor cable corroded out and fuse holder is burned from outside; battery clamps of sensor cable replaced, fuse and inside the fuse holder cleaned and checked, fuse holder wrapped in electrical tape; fuse holder requires replacement; long battery cable will require replacement in near future due to corrosion. Curiosity – passenger side battery sensor cable corroded out and fuse holder is burned from outside; battery clamps of sensor cable replaced, fuse and inside the fuse holder cleaned and checked, fuse holder wrapped in electrical tape; fuse holder requires replacement. Spirit – passenger side battery sensor cable corroded out and fuse holder is burned with the fuse from outside; battery clamps of sensor cable replaced; fuse holder with the fuse require replacement. Opportunity – passenger side battery sensor cable corroded out; battery clamps of sensor cable replaced; key switch is loosed and requires a washer. Sojourner – passenger and driver side battery sensor cable corroded out and fuse holder is burned from outside; battery clamps of sensor cable replaced, fuse and inside the fuse holder cleaned and checked, fuse holder wrapped in electrical tape; fuse holder requires replacement. All fuse holders are zip tight to the rover frame to prevent any contacts with the battery terminals. New parts are in order.

ATV: ATV’s Used: None. Nothing to report.

Cars:
Hab Car used and why, where: To Hanksville for supplies. Need to be serviced.
Crew Car used and why, where: To Hanksville for supplies.
General notes and comments: All cars awaiting renewed insurance ID.

Summary of Internet: All nominal.
EVA suits and radios:
Suits: All nominal
Comms: Headset #3 replaced due to absence on the ear cushion. All kits are labeled with new labels

Campus wide inspection, if action taken, what and why: One tunnel stick on the right from the rear airlock is corroded out at the ground level and needs to be replaced.
Summary of Hab Operations: New digital thermometer installed on the upper deck.
Summary of GreenHab Operations: Planted by crew 284. Moisture meter is broken and replacement is in order. New garden stakes received.
Summary of SciDome Operations: All nominal
Summary of Observatories Operations: All nominal.
Summary of RAM Operations: All toolkits are labeled with new labels.
Summary of Outpost Operations: All nominal.
Summary of Health and Safety Issues: All nominal.

Copyright © The Mars Society. All rights reserved. | Main Site